ProductsCatalogueInstallationPlug and Socket System EN 61535AC 166® G Cables

AC 166® G 3 pole

AC 166 NLCGB/ 3 - mains cables with socket

AC 166 NLCGB/ 3 - mains cables with socket

Technical data
Mouldingspolyamide 6/6, black or white
flammability rating to UL 94: V-2
continuous working temperature 100 °C
short-time temperature 160 °C
CablesH05VV-F (PVC)
continuous working temperature 70 °C
voltage rating: 300 V / 500 V, surge voltage 4 kV
wire ends with ferrules
Contactsbrass, plated
Current ratingto EN 60320: 16 A at T 70 °C
to EN 61984: 16 A at T 70 °C
Upper limit temperatureto EN 61984: 110°C
Conductor size1.5 mm²
Protection classIP20
IP40 - when plugged-in
Order info
DescriptionItemOrder No.PUDownload 
Cable 1.5 mm² PVC (H05VV-F) with rectangular Earthing Type Plug
1 metreAC 166 NLCGB/315 100 white9856531075Download CAD (stp-File)
 AC 166 NLCGB/315 100 black9856631075Download CAD (stp-File)
2 metresAC 166 NLCGB/315 200 white9856532050Download CAD (stp-File)
 AC 166 NLCGB/315 200 black9856632050Download CAD (stp-File)
x metresAC 166 NLCGB/315 x00 white985653x0 Download CAD (stp-File)
 AC 166 NLCGB/315 x00 black985663x0 Download CAD (stp-File)
Please replace the last three figures with the required length in cm. With the order no., please replace the last two figures for the required length in dm.
Click on item to add to or remove from the cart
Accessories
AC 166 VKE and VKH3 pole protective caps to seal inactive terminals
AC 166 VSE, VSF, VSLLatches
AC 166 GKU3 pole connecting links
AC 166 VSS12 pole locking pins
AC 166 GVT 3/33 pole distributing blocks (1 input, 2 output terminals)
AC 166 GVT 4/33 pole distributing blocks (1 input, 3 output terminals)
AC 166 GVT 6/33 pole distributing blocks (1 input, 5 output terminals)
Upon request
straight earthing type plug, cable size 2.5 mm²,
halogen-free cables; further product variants here