AC 166 BUF/315 WS
| Type | socket |
| connection type | screw |
| number of poles | 3 pole |
| coding |  |
| 1 (mains) white |
| colour | white |
| protection against incorrect plugging | yes |
| PE-function | yes |
| strain relief | yes |
| rated voltage | 250 V |
| rated current | 16 A |
| rated impulse voltage | 2.5 kV |
| cross-section rating | 2.5 mm² |
| cross-section rating (UL) | 14 AWG |
| clamping range | 0.5 - 4.0 mm² |
| sheathing cable diameter | 7.5 - 8.5 mm |
| type of conductor | fine stranded, stranded, solid |
| stripping length | 7.0 mm |
| dismantling length | 32.0 mm |
| dismantling length PE | 39.0 mm |
| clamping units per pole | 1 |
| pole marking | L ⏚ N |
| strain relief assembly | PZ 1 / ↻ 0.5 Nm |
| Tmax ambient air (at rated current) | 70 °C |
| Tmax component (operation) | 110 °C |
| Tmin component (operation) | -20 °C |
| IP Code acc. to EN 60529 | IP20 |
| IP Code when plugged | IP40 |
| insulator material |  |
| PA |
| contact material | brass |
| flammability rating acc. to UL 94 | V-2 |
All information subject to change without further notice